| Commercial Name | MKDens 25 | MKDens 36 |
| Type | C14SPV25MEF | C13SPV36MEF |
| Gas category | I2H (20) | I2H (20) |
| Draught type | Fortat | Fortat) |
| Combustion chamber | Etansa | Etansa |
| Energy Efficiency Band (natural gas) | A | A |
| Nox class (natural gas)ural) | 5 | 5 |
| Net efficiency at rated output (natural gas) | 96.7% | 96.7% |
| Net efficiency at 30% part-load (natural gas) | 106.7% | 106.7% |
| Maximum CH gross Heat input, Q | 26.6 kW | 36.3 kW |
| Minimum CH gross Heat input, Q | 5.2 kW | 8.1 kW |
| Maximum CH net Heat input, Q | 24.0 kW | 31.8 kW |
| Minimum CH net Heat input, Q | 4.7 kW | 7.3 kW |
| Maximum DHW gross Heat input, Q | 26.6 kW | 36.4 kW |
| Maximum DHW net Heat input, Q | 24.0 kW | 32.8 kW |
| Maximum CH heat output, P (at 100% load) | 24.3 kW | 32.3 kW |
| Minimum CH heat output, P | 4.9 kW | 7.6 kW |
| Maximum DHW output, P (at 100% load) | 24.5 kW | 33.3 kW |
|
Natural gas pressure on coupling (behind the reducer) Maximum inlet pressure |
20 mbar | 20 mbar |
|
Power supply Power consumption |
230V / 50 Hz 175 W |
230V / 50 Hz 175 W |
| Weight | 42 kg | 48 kg |
| Capacity of the heat exchanger | 1.75 l | 2.45 l |
| Maximum gas rate (natural gas) | 2.65 Nmc/h | 3.58 Nmc/h |
| Heating circuit - Flow rate | 0.8 mc/h | 0.8 mc/h |
| Heating circuit - Min. and max admitted pressure | 0.8 si 3 bar | 0.8 si 3 bar |
| Heating circuit - Outgoing water temperature | 30 - 80°C | 30 - 80°C |
| Connections - inlet-outlet CH | 3/4" | 3/4" |
| Connections - inlet-outlet DHW | 1/2" | 1/2" |
| Connections - gas supply | 3/4" | 3/4" |
| Dimensions (mm) Depth | 720 | 720 |
| Width | 420 | 420 |
| Height | 340 | 383 |
| With mounted elbow | 850 | 850 |
| Expansion vessel | 7 l | 8 l |
| Domestic Hot Water Temperature | 30 - 60°C | 30 - 60°C |
| DHW flow rate | ||
| ΔT= 25°C | 14.3 l/min | 20.6 l/min |
| ΔT= 35°C | 10.2 l/min | 14.7 l/min |
| ΔT= 40°C | 8 l/min | 11.5 l/min |
| Domestic cold water pressure | 0.2 - 8bar | 0.2 - 8bar |
| Flue gases temperature | 62 °C | 62 °C |
| Draught | 0.015 hPa | 0.015 hPa |
| Concentric flue kit - diameters | diam.100 / diam.60 | diam.100 / diam.60 |
| Twin flue kit - diameters | diam.80 / diam.80 | diam.80 / diam.80 |
|
Length of the concentric flue duct Lenght of the twin flue duct |
3m (maximum) 4m (maximum) |
3m (maximum) 4m (maximum) |
|
Guiding values Maximum water content in the installation |
150 l | 200 l |
| Name | Storage tank DHW |
| Type | BA120LPV |
| Maximum level of noise | < 50 dB(A) |
| Capacity of storage domestic hot water | 120 litters |
| Maximum pressure of domestic hot water | 8 bar |
| Test hydraulic pressure | 12 bar |
| Recommended maximum input pressure | 5 bar |
| Recommended maximum temperature domestic hot water | 65°C |
| Flow values domestic hot water | 16.5l / min. (Δt = 30°C) |
| Storage minimum temperature | 5°C |
| Expanssion vessel with membrane | 8 littres |
| Electric characteristics | 230V/50Hz - 135W |
| Netto weight (without water) | 61 kg |
| Grosso weight (with water) | 181 kg |
| Connections | |
| Inlet domestic cold water | 3/4" |
| Outlet domestic hot water | 3/4" |
| Outlet/Inlet circulating water | 3/4" |
| Dimensions | |
| Depth (mm) | 633 |
| Length (mm) | 500 |
| Height (mm) | 1105 |
| Denomination | MAX OPTIMUS |
| Type | C17 SPV 31 MEF |
| No. of type homologation certificate | CE |
| Draft | Forced |
| Burning chamber | Sealed |
| Maximum load efficiency | 93% |
| Minimum load efficiency | 92% |
| Effective thermal power (min/max) | 13 - 31 kW |
| Burner rated load (min/max) | 14.8 - 33.17 kW |
| Pressure of the gas | |
| Natural gas at the connection (after the reducing device) | 20 mBar |
| Natural gas at the inlet- maximum permitted pressure) | 35 mBar |
| LPG | 30-37 mBar |
| Supply voltage | 230 VAC, 50Hz |
| Absorbed electrical power | 160 W |
| Weight | 45 kg |
| Capacity of the heat exchanger | 1.8 l |
| Fuel consumption - natural gas (8500Kcal/Nm3) at maximum power | 3.34 - 1.40 Nm3/h |
| Fuel consumption - LPG (20425Kcal/Kg) at maximum power | 1.38 - 0.58 kg/h |
| Thermal heating | |
| Admitted maximum and minimum pressure | 0.5 and 3 Bar |
| Temperature on the heating circuit | 40-80°C |
|
Connections: inlet-outlet heating inlet-outlet hot domestic water gas feeding |
¾ ½ ¾ |
|
Dimensions: Depth (mm) Width (mm) Height (mm) Width the elbow installed (mm) |
325 435 730 855 |
| Expansion vessel with membrane | 8 l |
| Domestic hot water (DHW) preparing unit | |
| Range of temperature- DHW | 30-60°C |
|
Values of the flow rate Dt=25°C Dt=35°C Dt=45°C |
17.8 l/min 12.7 l/min 9.9 l/min |
| Pressure of the domestic cold water | 0.2-8 Bar |
| Temperature of the combustion gases | 147°C |
| Combustion gases connections (inlet-outlet) | Ø 100/Ø 60 mm |
| Length of the combustion gases connection | Maximum 3 m |
|
Informative values Maximum content of water in the unit Maximum surface of the enclosure |
200 l 250 m2 |
| Typecode | C15 MT SPV 24MEFM |
| Homologation Certificate number | CE |
| Draft | Forced |
| Burning chamber | Sealed |
| Maximum load efficiency | 92.7% |
| Minimum load efficiency | 93.7% |
| Effective thermal power (min/max) | 10 / 23.7 KW |
| Burner rated load (min/max) | 10.9 / 25.49 KW |
| Supply pressure: GN (after pressure reducer) | 20 mbar |
| Supply pressure: GN at imput, maximum allowed | 35 mbar |
| Supply pressure: GPL | 30-37 mbar |
| Supply voltage | 230 VAC, 50 Hz |
| Electrical power consumption | 160 W |
| Weight | 40 Kg |
| Heat exchanger capacity | 1 l |
| Fuel consumption G.N. (8.500 kcal/Nm3) at effective power (max/min) | 2.6 - 1.1 Nm 3/h |
| Fuel consumption GPL (20.425 kcal/kg) at max power | 1.07 - 0.4 kg/h |
| Piping | |
| Minimum and maximum pressure allowed in the heating circuit | 0.5 to 3 bar |
| Temperature control range in the heating circuit | 40 - 80 °C |
| Warm water circuit | |
| Temperature control range | 30 - 60 °C |
|
Continuous flowrate at: ΔT=25 °C ΔT=35 °C ΔT=45 °C |
13.5 l/min 9.7 l/min 7.5 l/min |
|
Nipples: In - out heating In - out warm water Gas supply |
¾" ½" ¾" |
|
Size: Depth Width Height Height including exhaust |
275 mm 415 mm 700 mm 825 mm |
| Exhaust gases temperature at noinal load | 142,4 °C |
| Exhaust gases joint (intake/exhaust) | Ø100 / Ø60 mm |
| Exhaust gases joint lenght | max 3 m |
|
Guidance values: Max water amount in circuit Max indoor heated area |
150 l 150 m2 |
| Denomination | MOTAN KSTART | MOTAN KPLUS |
| Type | C21 SPV 23 MEF | C22 SPV 23 MEF |
| Energetical efficiency symbol | *** | *** |
| Category | II2H | II2H |
| Draft | Forced | Forced |
| Combustion chamber | Sealed | Sealed |
| Efficiency at rated output - natural gases* |
93% | 93% |
| Nox class - natural gases* |
3 | 2 |
| Rated output | 23,2kW | 22,8kW |
| Minimum output | 9,4 kW | 9,4 kW |
| Burner rated load | 24,78 kW | 24,44 kW |
| Gas pressure NG at connection (after the reducer) | 20 mbar | 20 mbar |
| Electrical characteristics | 230V/50Hz 130 W |
230V/50Hz 130 W |
| Weight | 33 kg | 33 kg |
| Capacity of the heat exchanger | 1 l | 1 l |
| Maximum rated fuel consumption N.G. | 2,59 Nmc/h | 2,56 Nmc/h |
| Central heating | ||
| Thermal agent flow | 0,8 m3/h | 0,8 m3/h |
| Minimum and maximum admitted pressure | 0,5 și 3 bar | 0,5 și 3 bar |
| Temperature on the heating circuit | 30 - 80°C | 30 - 80°C |
| Connections | ||
| inlet - outlet central heating | 3/4" | 3/4" |
| DHW inlet-outlet | 1/2" | 1/2" |
| gas supply | 3/4" | 3/4" |
| Dimensions | ||
| length (mm) | 700 | 700 |
| Width (mm) | 425 | 425 |
| depth (mm) | 277 | 277 |
| With mounted elbow (mm) | 850 | 850 |
| Expansion vessel with membrane | 7 l | 7 l |
| Hot domestic water producer | ||
| DHW temperature | 30 - 60°C | 30 - 60°C |
| Flow values | ||
| Δt = 25°C | 13,2 l/min | 13,2 l/min |
| Δt = 35°C | 9,4 l/min | 9,4 l/min |
| Δt = 45°C | 7,4 l/min | 7,4 l/min |
| Pressure | 0,2 - 8 bar | 0,2 - 8 bar |
| Exhaust gases (temperature) | 125°C | 130°C |
| Depression necessary on the stack | 0.015 hPa | 0.015 hPa |
| Ehaust gases connection (inlet-outlet) | Φ 100 / Φ 60 | Φ 100 / Φ 60 |
| Length of the flue gases connection | maximum 3m | maximum 3m |
| Guiding values | ||
| Water content into the installation | 150 l | 150 l |
| Maximum surface of the enclosure | 200 m2 | 200 m2 |
|
General technical data and functional parameters
|
C 11 N
natural draft |
C 11 F
forced draft |
C 12 N
natural draft |
C 12 F
forced draft |
||||||||||||||||
|
|
|
|
|
||||||||||||||||
|
Minimum guaranteed efficiency
|
93%
|
93%
|
93%
|
93%
|
||||||||||||||||
|
|
|
|
|
||||||||||||||||
|
Weight
|
37 kg
|
39 kg
|
37 kg
|
39 kg
|
||||||||||||||||
|
Heating temperature
|
30-80 °C
|
30-80 °C
|
30-80 °C
|
30-80 °C
|
||||||||||||||||
|
DHW temperature
|
30-60 °C
|
30-60 °C
|
30-60 °C
|
30-60 °C
|
||||||||||||||||
|
DHW flow at ΔT=25°C
|
13,8 l/min
|
13,8 l/min
|
13,8 l/min
|
13,8 l/min
|
||||||||||||||||
|
DHW flow at ΔT=35°C
|
9,8 l/min
|
9,8 l/min
|
9,8 l/min
|
9,8 l/min
|
||||||||||||||||
|
Max. input electrical power
|
90 W
|
130 W
|
90 W
|
130 W
|
||||||||||||||||
|
Expansion vessel capacity
|
7 liters
|
7 liters
|
7 liters
|
7 liters
|
||||||||||||||||
|
Max amount of water in boiler
|
150 litres
|
150 litres
|
150 litres
|
150 litres
|
||||||||||||||||
|
Domestic water pressure
|
0,2-8 bar
|
0,2-8 bar
|
0,2-8 bar
|
0,2-8 bar
|
||||||||||||||||
|
Rated max. fuel consumption
|
2,62 N m3/h
|
2,62 N m3/h
|
2,62 N m3/h
|
2,62 N m3/h
|
Download detailed technical information about the running of the MOTAN boilers, in Adobe Reader format. ![]()
| Name | Room digital thermostat |
| Type | WT 190 |
| Temperature measurement | 0ºC - 40ºC |
| Accuracy | +/- 0,5ºC |
| Temperature controllable range | 5ºC - 35ºC |
| Resolution | 0,5ºC |
| Power supply | 2 x 1,5V AAA alkaline batteries |
| Rating | 24V ; 50-60Hz ; 1A Max |
| Terminals | 2 sqmm cable |
| Operating temperature | 0 - 50ºC |
| Storage temperature | -5 - 50ºC |
| Sensing element | termistor NTC |
KÖBER Ltd Vaduri Branch - the producer of MOTAN wall hung gas boilers participated as exhibitor at the International fair Mostra Convegno EXPOCONFORT Milano 2010. It is KOBER's second consecutive participation at MCE Expoconfort. Within the exhibition, we exhibit all the MOTAN range of products MOTAN: MOTAN MKDens 25, MOTAN MKDens 36, MOTAN MAXOPTIMUS, MOTAN OPTIMUS, MOTAN START, MOTAN PLUS, MOTAN KPLUS as well as Storage Tank BA120LPV.
Please find a selection of images from MOSTRA CONVEGNO EXPOCONFORT here.
MOTAN MKDens25 and MKDens 36 condensing wall hung gas boilers constituted the novelty for MOTAN stand. These two models was launched in August 2009 and have "CE" type examination certificate The MKDens MOTAN type have "CE" type examination certificate issued by Gemanischer Lloyd Industrial Services (Germany) following the tests carried out in 2 laboratories from UK. Following the tests results, both models reached A Energy Efficiency Band (natural gas) (Sedbuk A), with 106,7% net efficiency at 30% part-load (natural gas) at MKDens 25 model and 106,5% net efficiency at 30% part-load (natural gas) at MKDens 36 model.
Commissioning and service is free throughout the warranty period that is of 3 years for all models of boilers.